2VAC5-585-1680. Mechanical warewashing equipment, hot water sanitization temperatures.
A. Except as specified in subsection B of this section, in a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 194°F (90°C), or less than:Pf
1. For a stationary rack, single temperature machine, 165°F (74°C);Pf or
2. For all other machines, 180°F (82°C).Pf
B. The maximum temperature specified under subsection A of this section does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 32, Issue 22, eff. July 12, 2016.