13VAC5-63-295. Chapter 23 Wood.

A. Change Item 2 of Section 2308.2.3 of the IBC to read:

2. Live loads shall not exceed 40 psf (1916 N/m2) for floors.

Exception: Concrete slab-on-grade live load limited only by allowable soil bearing pressure.

B. Change Table 2308.4.1.1(1) of the IBC to read:

Table 2308.4.1.1(1)

Header and Girder Spansa, b for Exterior Bearing Walls

(Maximum spans for Douglas Fir-Larch, Hem-Fir, Southern Pine, and Spruce-Pine-Firb and required number of jack studs)

Girders and Headers Supporting

Size

Ground Snow Load (psf)e

30

50

70

Building Widthc (feet)

12

24

36

12

24

36

12

24

36

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Spanf

NJd

Roof and ceiling

1‑2 x 6

4‑0

1

3‑1

2

2‑7

2

3‑5

1

2‑8

2

2‑3

2

3‑0

2

2‑4

2

2‑0

2

1‑2 x 8

5‑1

2

3‑11

2

3‑3

2

4‑4

2

3‑4

2

2‑10

2

3‑10

2

3‑0

2

2‑6

3

1‑2 x 10

6‑0

2

4‑8

2

3‑11

2

5‑2

2

4‑0

2

3‑4

2

4‑7

2

3‑6

3

3‑0

3

1‑2 x 12

7‑1

2

5‑5

2

4‑7

3

6‑1

2

4‑8

3

3‑11

3

5‑5

2

4‑2

3

3‑6

3

2‑2 x 4

4‑0

1

3‑1

1

2‑7

1

3‑5

1

2‑7

1

2‑2

1

3‑0

1

2‑4

1

2‑0

1

2‑2 x 6

6‑0

1

4‑7

1

3‑10

1

5‑1

1

3‑11

1

3‑3

2

4‑6

1

3‑6

2

2‑11

2

2‑2 x 8

7‑7

1

5‑9

1

4‑10

2

6‑5

1

5‑0

2

4‑2

2

5‑9

1

4‑5

2

3‑9

2

2‑2 x 10

9‑0

1

6‑10

2

5‑9

2

7‑8

2

5‑11

2

4‑11

2

6‑9

2

5‑3

2

4‑5

2

2‑2 x 12

10‑7

2

8‑1

2

6‑10

2

9‑0

2

6‑11

2

5‑10

2

8‑0

2

6‑2

2

5‑2

3

3‑2 x 8

9‑5

1

7‑3

1

6‑1

1

8‑1

1

6‑3

1

5‑3

2

7‑2

1

5‑6

2

4‑8

2

3‑2 x 10

11‑3

1

8‑7

1

7‑3

2

9‑7

1

7‑4

2

6‑2

2

8‑6

1

6‑7

2

5‑6

2

3‑2 x 12

13‑2

1

10‑1

2

8‑6

2

11‑3

2

8‑8

2

7‑4

2

10‑0

2

7‑9

2

6‑6

2

4‑2 x 8

10‑11

1

8‑4

1

7‑0

1

9‑4

1

7‑2

1

6‑0

1

8‑3

1

6‑4

1

5‑4

2

4‑2 x 10

12‑11

1

9‑11

1

8‑4

1

11‑1

1

8‑6

1

7‑2

2

9‑10

1

7‑7

2

6‑4

2

4‑2 x 12

15‑3

1

11‑8

1

9‑10

2

13‑0

1

10‑0

2

8‑5

2

11‑7

1

8‑11

2

7‑6

2

Roof, ceiling, and one center-bearing floor

1‑2 x 6

3‑3

1

2‑7

2

2‑2

2

3‑0

2

2‑4

2

2‑0

2

2‑9

2

2‑2

2

1‑10

2

1‑2 x 8

4‑1

2

3‑3

2

2‑9

2

3‑9

2

3‑0

2

2‑6

3

3‑6

2

2‑9

2

2‑4

3

1‑2 x 10

4‑11

2

3‑10

2

3‑3

3

4‑6

2

3‑6

3

3‑0

3

4‑1

2

3‑3

3

2‑9

3

1‑2 x 12

5‑9

2

4‑6

3

3‑10

3

5‑3

2

4‑2

3

3‑6

3

4‑10

3

3‑10

3

3‑3

4

2‑2 x 4

3‑3

1

2‑6

1

2‑2

1

3‑0

1

2‑4

1

2‑0

1

2‑8

1

2‑2

1

1‑10

1

2‑2 x 6

4‑10

1

3‑9

1

3‑3

2

4‑5

1

3‑6

2

3‑0

2

4‑1

1

3‑3

2

2‑9

2

2‑2 x 8

6‑1

1

4‑10

2

4‑1

2

5‑7

2

4‑5

2

3‑9

2

5‑2

2

4‑1

2

3‑6

2

2‑2 x 10

7‑3

2

5‑8

2

4‑10

2

6‑8

2

5‑3

2

4‑5

2

6‑1

2

4‑10

2

4‑1

2

2‑2 x 12

8‑6

2

6‑8

2

5‑8

2

7‑10

2

6‑2

2

5‑3

3

7‑2

2

5‑8

2

4‑10

3

3‑2 x 8

7‑8

1

6‑0

1

5‑1

2

7‑0

1

5‑6

2

4‑8

2

6‑5

1

5‑1

2

4‑4

2

3‑2 x 10

9‑1

1

7‑2

2

6‑1

2

8‑4

1

6‑7

2

5‑7

2

7‑8

2

6‑1

2

5‑2

2

3‑2 x 12

10‑8

2

8‑5

2

7‑2

2

9‑10

2

7‑8

2

6‑7

2

9‑0

2

7‑1

2

6‑1

2

4‑2 x 8

8‑10

1

6‑11

1

5‑11

1

8‑1

1

6‑4

1

5‑5

2

7‑5

1

5‑11

1

5‑0

2

4‑2 x 10

10‑6

1

8‑3

2

7‑0

2

9‑8

1

7‑7

2

6‑5

2

8‑10

1

7‑0

2

6‑0

2

4‑2 x 12

12‑4

1

9‑8

2

8‑3

2

11‑4

2

8‑11

2

7‑7

2

10‑4

2

8‑3

2

7‑0

2

Roof, ceiling, and one clear span roof

1‑2 x 6

2‑11

2

2‑3

2

1‑11

2

2‑9

2

2‑1

2

1‑9

2

2‑7

2

2‑0

2

1‑8

2

1‑2 x 8

3‑9

2

2‑10

2

2‑5

3

3‑6

2

2‑8

2

2‑3

3

3‑3

2

2‑6

3

2‑2

3

1‑2 x 10

4‑5

2

3‑5

3

2‑10

3

4‑2

2

3‑2

3

2‑8

3

3‑11

2

3‑0

3

2‑6

3

1‑2 x 12

5‑2

2

4‑0

3

3‑4

3

4‑10

3

3‑9

3

3‑2

4

4‑7

3

3‑6

3

3‑0

4

2‑2 x 4

2‑11

1

2‑3

1

1‑10

1

2‑9

1

2‑1

1

1‑9

1

2‑7

1

2‑0

1

1‑8

1

2‑2 x 6

4‑4

1

3‑4

2

2‑10

2

4‑1

1

3‑2

2

2‑8

2

3‑10

1

3‑0

2

2‑6

2

2‑2 x 8

5‑6

2

4‑3

2

3‑7

2

5‑2

2

4‑0

2

3‑4

2

4‑10

2

3‑9

2

3‑2

2

2‑2 x 10

6‑7

2

5‑0

2

4‑2

2

6‑1

2

4‑9

2

4‑0

2

5‑9

2

4‑5

2

3‑9

3

2‑2 x 12

7‑9

2

5‑11

2

4‑11

3

7‑2

2

5‑7

2

4‑8

3

6‑9

2

5‑3

3

4‑5

3

3‑2 x 8

6‑11

1

5‑3

2

4‑5

2

6‑5

1

5‑0

2

4‑2

2

6‑1

1

4‑8

2

4‑0

2

3‑2 x 10

8‑3

2

6‑3

2

5‑3

2

7‑8

2

5‑11

2

5‑0

2

7‑3

2

5‑7

2

4‑8

2

3‑2 x 12

9‑8

2

7‑5

2

6‑2

2

9‑0

2

7‑0

2

5‑10

2

8‑6

2

6‑7

2

5‑6

3

4‑2 x 8

8‑0

1

6‑1

1

5‑1

2

7‑5

1

5‑9

2

4‑10

2

7‑0

1

5‑5

2

4‑7

2

4‑2 x 10

9‑6

1

7‑3

2

6‑1

2

8‑10

1

6‑10

2

5‑9

2

8‑4

1

6‑5

2

5‑5

2

4‑2 x 12

11‑2

2

8‑6

2

7‑2

2

10‑5

2

8‑0

2

6‑9

2

9‑10

2

7‑7

2

6‑5

2

Roof, ceiling, and two center-bearing floors

1‑2 x 6

2‑8

2

2‑1

2

1‑10

2

2‑7

2

2‑0

2

1‑9

2

2‑5

2

1‑11

2

1‑8

2

1‑2 x 8

3‑5

2

2‑8

2

2‑4

3

3‑3

2

2‑7

2

2‑2

3

3‑1

2

2‑5

3

2‑1

3

1‑2 x 10

4‑0

2

3‑2

3

2‑9

3

3‑10

2

3‑1

3

2‑7

3

3‑8

2

2‑11

3

2‑5

3

1‑2 x 12

4‑9

3

3‑9

3

3‑2

4

4‑6

3

3‑7

3

3‑1

4

4‑3

3

3‑5

3

2‑11

4

2‑2 x 4

2‑8

1

2‑1

1

1‑9

1

2‑6

1

2‑0

1

1‑8

1

2‑5

1

1‑11

1

1‑7

1

2‑2 x 6

4‑0

1

3‑2

2

2‑8

2

3‑9

1

3‑0

2

2‑7

2

3‑7

1

2‑10

2

2‑5

2

2‑2 x 8

5‑0

2

4‑0

2

3‑5

2

4‑10

2

3‑10

2

3‑3

2

4‑7

2

3‑7

2

3‑1

2

2‑2 x 10

6‑0

2

4‑9

2

4‑0

2

5‑8

2

4‑6

2

3‑10

3

5‑5

2

4‑3

2

3‑8

3

2‑2 x 12

7‑0

2

5‑7

2

4‑9

3

6‑8

2

5‑4

3

4‑6

3

6‑4

2

5‑0

3

4‑3

3

3‑2 x 8

6‑4

1

5‑0

2

4‑3

2

6‑0

1

4‑9

2

4‑1

2

5‑8

2

4‑6

2

3‑10

2

3‑2 x 10

7‑6

2

5‑11

2

5‑1

2

7‑1

2

5‑8

2

4‑10

2

6‑9

2

5‑4

2

4‑7

2

3‑2 x 12

8‑10

2

7‑0

2

5‑11

2

8‑5

2

6‑8

2

5‑8

3

8‑0

2

6‑4

2

5‑4

3

4‑2 x 8

7‑3

1

5‑9

1

4‑11

2

5‑11

1

5‑6

2

4‑8

2

6‑7

1

5‑2

2

4‑5

2

4‑2 x 10

8‑8

1

6‑10

2

5‑10

2

8‑3

2

6‑6

2

5‑7

2

7‑10

2

6‑2

2

5‑3

2

4‑2 x 12

10‑2

2

8‑1

2

6‑10

2

9‑8

2

7‑8

2

6‑7

2

9‑2

2

7‑3

2

6‑2

2

Roof, ceiling, and two clear span floors

1‑2 x 6

2‑3

2

1‑9

2

1‑5

2

2‑3

2

1‑9

2

1‑5

3

2‑2

2

1‑8

2

1‑5

3

1‑2 x 8

2‑10

2

2‑2

3

1‑10

3

2‑10

2

2‑2

3

1‑10

3

2‑9

2

2‑1

3

1‑10

3

1‑2 x 10

3‑4

2

2‑7

3

2‑2

3

3‑4

3

2‑7

3

2‑2

4

3‑3

3

2‑6

3

2‑2

4

1‑2 x 12

4‑0

3

3‑0

3

2‑7

4

4‑0

3

3‑0

4

2‑7

4

3‑10

3

3‑0

4

2‑6

4

2‑2 x 4

2‑3

1

1‑8

1

1‑4

1

2‑3

1

1‑8

1

1‑4

1

2‑2

1

1‑8

1

1‑4

2

2‑2 x 6

3‑4

1

2‑6

2

2‑2

2

3‑4

2

2‑6

2

2‑2

2

3‑3

2

2‑6

2

2‑1

2

2‑2 x 8

4‑3

2

3‑3

2

2‑8

2

4‑3

2

3‑3

2

2‑8

2

4‑1

2

3‑2

2

2‑8

3

2‑2 x 10

5‑0

2

3‑10

2

3‑2

3

5‑0

2

3‑10

2

3‑2

2

4‑10

2

3‑9

3

3‑2

3

2‑2 x 12

5‑11

2

4‑6

3

3‑9

3

5‑11

2

4‑6

3

3‑9

3

5‑8

2

4‑5

3

3‑9

3

3‑2 x 8

5‑3

1

4‑0

2

3‑5

2

5‑3

2

4‑0

2

3‑5

2

5‑1

2

3‑11

2

3‑4

2

3‑2 x 10

6‑3

2

4‑9

2

4‑0

2

6‑3

2

4‑9

2

4‑0

2

6‑1

2

4‑8

2

4‑0

3

3‑2 x 12

7‑5

2

5‑8

2

4‑9

3

7‑5

2

5‑8

2

4‑9

3

7‑2

2

5‑6

3

4‑8

3

4‑2 x 8

6‑1

1

4‑8

2

3‑11

2

6‑1

1

4‑8

2

3‑11

2

5‑11

1

4‑7

2

3‑11

2

4‑2 x 10

7‑3

2

5‑6

2

4‑8

2

7‑3

2

5‑6

2

4‑8

2

7‑0

2

5‑5

2

4‑7

2

4‑2 x 12

8‑6

2

6‑6

2

5‑6

2

8‑6

2

6‑6

2

5‑6

2

8‑3

2

6‑4

2

5‑4

3

For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa.

a. Spans are given in feet and inches.

b. Spans are based on the minimum design properties for No. 2 grade lumber of Douglas Fir‑Larch, Hem‑Fir, Southern Pine, and Spruce‑Pine Fir.

c. Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be interpolated.

d. NJ - Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is permitted to be supported by an approved framing anchor attached to the full‑height wall stud and to the header.

e. Use 30 psf ground snow load for cases in which ground snow load is less than 30 psf and the roof live load is equal to or less than 20 psf.

f. Spans are calculated assuming the top of the header or girder is laterally braced by perpendicular framing. Where the top of the header or girder is not laterally braced (e.g. cripple studs bearing on the header), tabulated spans for headers consisting of 2x8, 2x10, or 2x12 sizes shall be multiplied by 0.70 or the header shall be designed.

C. Change Table 2308.4.1.1(2) of the IBC to read:

Table 2308.4.1.1(2)

Header and Girder Spansa, b for Interior Bearing Walls

(Maximum spans for Douglas Fir-Larch, Hem-Fir, Southern Pine, and Spruce-Pine-Firb and required number of jack studs)

Headers and Girders Supporting

Size

Building Widthc(feet)

12

24

36

Spane

NJd

Spane

NJd

Spane

NJd

One floor only

2‑2 x 4

4‑1

1

2‑10

1

2‑4

1

2‑2 x 6

6‑1

1

4‑4

1

3‑6

1

2‑2 x 8

7‑9

1

5‑5

1

4‑5

2

2‑2 x 10

9‑2

1

6‑6

2

5‑3

2

2‑2 x 12

10‑9

1

7‑7

2

6‑3

2

3‑2 x 8

9‑8

1

6‑10

1

5‑7

1

3‑2 x 10

11‑5

1

8‑1

1

6‑7

2

3‑2 x 12

13‑6

1

9‑6

2

7‑9

2

4‑2 x 8

11‑2

1

7‑11

1

6‑5

1

4‑2 x 10

13‑3

1

9‑4

1

7‑8

1

4‑2 x 12

15‑7

1

11‑0

1

9‑0

2

Two floors

2‑2 x 4

2‑7

1

1‑11

1

1‑7

1

2‑2 x 6

3‑11

1

2‑11

2

2‑5

2

2‑2 x 8

5‑0

1

3‑8

2

3‑1

2

2‑2 x 10

5‑11

2

4‑4

2

3‑7

2

2‑2 x 12

6‑11

2

5‑2

2

4‑3

3

3‑2 x 8

6‑3

1

4‑7

2

3‑10

2

3‑2 x 10

7‑5

1

5‑6

2

4‑6

2

3‑2 x 12

8‑8

2

6‑5

2

5‑4

2

4‑2 x 8

7‑2

1

5‑4

1

4‑5

2

4‑2 x 10

8‑6

1

6‑4

2

5‑3

2

4‑2 x 12

10‑1

1

7‑5

2

6‑2

2

a. Spans are given in feet and inches.

b. Spans are based on the minimum design properties for No. 2 grade lumber of Douglas Fir‑Larch, Hem‑Fir, Southern Pine, and Spruce‑Pine Fir.

c. Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be interpolated.

d. NJ - Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is permitted to be supported by an approved framing anchor attached to the full‑height wall stud and to the header.

e. Spans are calculated assuming the top of the header or girder is laterally braced by perpendicular framing. Where the top of the header or girder is not laterally braced (e.g., cripple studs bearing on the header), tabulated spans for headers consisting of 2x8, 2x10, or 2x12 sizes shall be multiplied by 0.70 or the header shall be designed.

Statutory Authority

§ 36-98 of the Code of Virginia.

Historical Notes

Derived from Volume 30, Issue 16, eff. July 14, 2014; amended, Virginia Register Volume 34, Issue 18, eff. September 4, 2018.

Website addresses provided in the Virginia Administrative Code to documents incorporated by reference are for the reader's convenience only, may not necessarily be active or current, and should not be relied upon. To ensure the information incorporated by reference is accurate, the reader is encouraged to use the source document described in the regulation.

As a service to the public, the Virginia Administrative Code is provided online by the Virginia General Assembly. We are unable to answer legal questions or respond to requests for legal advice, including application of law to specific fact. To understand and protect your legal rights, you should consult an attorney.