9VAC5-40-1680. Standard for particulate matter.
No owner or other person shall cause or permit to be discharged into the atmosphere from any group of similar affected facilities specified below any particulate emissions in excess of the following limits:
Affected Facility | Maximum Allowable Emission of Particulate in Lb/Equivalent Ton of Air Dried Pulp |
All Recovery Furnace Units | 3.00 |
All Smelt Dissolving Tank Units | 0.75 |
All Lime Kiln Units | 1.00 |
All Slaker Tank Units | 0.30 |
Statutory Authority
§§ 10.1-1307 and 10.1-1308 of the Code of Virginia.
Historical Notes
Derived from VR120-04-1303, eff. January 1, 1985.