12VAC5-421-3080. Lighting, intensity.
The light intensity shall be:
1. At least 10 foot candles (108 lux) at a distance of 30 inches (75 cm) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning;
2. At least 20 foot candles (215 lux):
a. At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption;
b. Inside equipment such as reach-in and under-counter refrigerators;
c. At a distance of 30 inches (75 cm) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and
3. At least 50 foot candles (540 lux) at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
Statutory Authority
§§ 35.1-11 and 35.1-14 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 18, Issue 10, eff. March 1, 2002; amended, Virginia Register Volume 26, Issue 7, eff. January 1, 2010.