LIS

Administrative Code

Creating a Report: Check the sections you'd like to appear in the report, then use the "Create Report" button at the bottom of the page to generate your report. Once the report is generated you'll then have the option to download it as a pdf, print or email the report.

Virginia Administrative Code
Title 12. Health
Agency 5. Department of Health
Chapter 610. Sewage Handling and Disposal Regulations
10/5/2024

12VAC5-610-594. In-ground systems.

Article 2

Systems Using Naturally Occurring Undisturbed Soil

A. An in-ground system is a system which utilizes a natural, undisturbed soil horizon to treat and disperse effluent where the infiltrative surface is placed 18 inches or more beneath the original surface of the ground. In-ground systems include, but are not limited to, conventional septic tank drainfield systems, chamber systems, alternative aggregate systems, enhanced flow systems, and pressure dosed systems.

B. Septic tank effluent. Septic tank effluent may be utilized in an in-ground system when all of the site and soil criteria of this subsection are met. Also see Table 4.3.

1. Horizon. The soil horizon(s) for the 18 inches immediately below the installation depth shall not show the presence of any limiting factor. Limiting factors include bedrock, seasonal or permanent water table, pans, or other impervious strata.

2. Separation distances. Table 4.2 contains the minimum setback distances between an absorption field and various structures or topographic features.

3. Estimated or measured infiltration rates. The estimated or measured infiltration rate shall not exceed 120 minutes per inch within any part of the sidewall area of the trench or within 18 inches of the infiltrative interface where effluent encounters undisturbed soil.

C. Soil criteria when utilizing secondary effluent. Secondary effluent may be utilized in an in-ground system when all of the criteria of this subsection are met. Also see Table 4.3.

1. Horizon. The soil horizon(s) for the 12 inches immediately below the installation depth shall not show the presence of any limiting factor. Limiting factors include bedrock, seasonal or permanent water table, pans or other impervious strata.

2. Separation distances. Table 4.2 contains the minimum setback distances between an absorption field and various structures or topographic features.

3. Estimated or measured infiltration rates. The estimated or measured infiltration rate shall not exceed 120 minutes per inch within the sidewall area of the trench, if any, or within 12 inches of the infiltrative interface where effluent encounters undisturbed soil.

Statutory Authority

§§ 32.1-12 and 32.1-164 of the Code of Virginia.

Historical Notes

Derived from Virginia Register Volume 16, Issue 16, eff. July 1, 2000.

Website addresses provided in the Virginia Administrative Code to documents incorporated by reference are for the reader's convenience only, may not necessarily be active or current, and should not be relied upon. To ensure the information incorporated by reference is accurate, the reader is encouraged to use the source document described in the regulation.

As a service to the public, the Virginia Administrative Code is provided online by the Virginia General Assembly. We are unable to answer legal questions or respond to requests for legal advice, including application of law to specific fact. To understand and protect your legal rights, you should consult an attorney.