6VAC15-81-620. Pedestrian sally ports.
A. Sally ports shall be provided at any point the secure perimeter of the building is penetrated unless specifically exempted by this chapter.
B. Sally ports shall be provided at all exterior openings from security areas and at the entrances to housing units designed for maximum and medium security inmates.
C. Any stairwell with a door that penetrates the secure perimeter shall be constructed as a sally port.
D. For an emergency exits only, an exterior area enclosed with bar grille or woven rod may serve as the second barrier of a sally port. This sally port shall be provided with a top barrier at least equivalent to the vertical enclosure fence mesh and the area is supervised by CCTV.
E. Exterior security doors used solely to meet emergency evacuation requirements are not required to be sally ported, however, fencing the area to be utilized for evacuation is required if no sally port is provided.
F. Commercial grade sectional doors or overhead rolling doors are not considered secure and shall not be part of a sally port.
G. Consideration shall be given to providing weapon lockers equipped with individually locked compartments at the entry of staff and law-enforcement sally ports penetrating the secure perimeter.
Statutory Authority
§§ 53.1-5, 53.1-80, and 53.1-82 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 34, Issue 12, eff. March 8, 2018.