Article 4. Sewage, Other Liquid Waste, and Rainwater
2VAC5-585-2500. Mobile holding tank capacity and drainage.
A sewage holding tank in a mobile food establishment shall be:
1. Sized 15% larger in capacity than the water supply tank; and
2. Sloped to a drain that is one inch (25 mm) in inner diameter or greater, equipped with a shut-off valve.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007.
2VAC5-585-2505. Establishment drainage system.
Food establishment drainage systems, including grease traps, that convey sewage shall be designed and installed as specified under 2VAC5-585-2180 A.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 32, Issue 22, eff. July 12, 2016.
2VAC5-585-2510. (Repealed.)
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; repealed, Virginia Register Volume 26, Issue 7, eff. January 1, 2010.
2VAC5-585-2520. Backflow prevention.
A. Except as specified in subsections B, C, and D of this section, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.P
B. Subsection A of this section does not apply to floor drains that originate in refrigerated spaces that are constructed as an integral part of the building.
C. If allowed by law, a warewashing machine may have a direct connection between its waste outlet and a floor drain when the machine is located within five feet (1.5 meters) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap.
D. If allowed by law, a warewashing sink may have a direct connection.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 26, Issue 7, eff. January 1, 2010; Volume 32, Issue 22, eff. July 12, 2016; Volume 37, Issue 19, eff. June 24, 2021.
2VAC5-585-2530. Grease trap.
If used, a grease trap shall be located to be easily accessible for cleaning.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007.
2VAC5-585-2540. Conveying sewage.
Sewage shall be conveyed to the point of disposal through an approved sanitary sewage system or other system, including use of sewage transport vehicles, waste retention tanks, pumps, pipes, hoses, and connections that are constructed, maintained, and operated according to law.P
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 32, Issue 22, eff. July 12, 2016.
2VAC5-585-2550. Removing mobile food establishment wastes.
Sewage and other liquid wastes shall be removed from a mobile food establishment at an approved waste servicing area or by a sewage transport vehicle in such a way that a public health hazard or nuisance is not created.Pf
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 32, Issue 22, eff. July 12, 2016.
2VAC5-585-2560. Flushing a waste retention tank.
A tank for liquid waste retention shall be thoroughly flushed and drained in a sanitary manner during the servicing operation.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007.
2VAC5-585-2570. Approved sewage disposal system.
Sewage shall be disposed through an approved facility that is:
1. A public sewage treatment plant;P or
2. An individual sewage disposal system that is sized, constructed, maintained, and operated in accordance with the regulations promulgated pursuant to Chapter 6 (§ 32.1-163 et seq.) of Title 32.1 of the Code of Virginia or in accordance with the related local ordinance.P
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; amended, Virginia Register Volume 32, Issue 22, eff. July 12, 2016; Volume 37, Issue 19, eff. June 24, 2021.
2VAC5-585-2580. Other liquid wastes and rainwater.
Condensate drainage and other nonsewage liquids and rainwater shall be drained from point of discharge to disposal according to law.
Statutory Authority
§ 3.2-5121 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007.