Part X. Analyzer System Certification and Specifications for Enhanced Emissions Inspection Programs
9VAC5-91-640. Applicability.
Analyzer System Certification and Specifications for Enhanced Emissions Inspection Programs
A. The provisions of this chapter apply to any system used for measuring or determining exhaust gases and evaporative emissions from motor vehicles in the Virginia Motor Vehicle Emissions Control Program.
B. No owner or other person shall conduct emissions inspections required by the Virginia Vehicle Emissions Control Program pursuant to this chapter unless the analyzer system used to perform such inspections is certified by the department and such other required equipment meets the provision of this chapter.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-650. Design goals.
A. The analyzer system shall be designed for maximum operational simplicity with a minimum number of operational decisions required by the emissions inspector in the performance of a complete emissions analysis including exhaust tests, other emissions-related electronic or mechanical tests, or a combination of such tests.
B. The analyzer system shall be unaffected by ambient conditions in a typical emissions inspection station environment and its use shall be primarily for compliance inspection purposes. It shall be capable of providing emissions characteristics, independent of the inspection function, which can be used for vehicle diagnostic work as well.
C. The analyzer system shall be of a design which can perform both ASM and OBD testing using an analyzer certified under 9VAC5-91-680 with the addition of a dynamometer.
D. The analyzer shall be readily upgradable, without replacing the existing central processing unit, to incorporate on-board diagnostic (OBD) testing equipment and additional electronic vehicle identification equipment such as video and audio processes.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-660. Warranty; service contract (effective during periods without a designated program coordinator).
A. A certified emissions analyzer system shall include, at a minimum, a one-year warranty, including parts and labor, which shall begin on the day that the emissions inspection station is permitted by the department, or that the emissions analyzer system is installed and operational, whichever is later. The disk drive system in the central processing unit shall be warranted for two years.
B. Emissions analyzer system manufacturers or vendors shall offer, at a price to be stated at the time such system is offered for sale, an extended warranty for an additional five years beyond the initial one-year warranty.
C. Emissions analyzer system manufacturers or vendors shall offer, at a price to be stated at the time such system is offered for sale, a maintenance service contract for the period of time remaining from the startup date to a date six years afterward.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-665. Warranty; service contract with program coordinator.
A. On or after July 1, 2013, and upon designation of a program coordinator, a service contract approved by the department shall be established between each inspection station owner and the program coordinator providing, at a minimum, the following services:
1. The delivery, installation, calibration, and verification of the proper operating condition of an analyzer system that has been certified in writing by the department.
2. The instruction of all inspectors currently employed by the emissions inspection station at the time of installation, to include:
a. The proper use, maintenance, and operation of the exhaust analyzer system;
b. The step-by-step procedure for performing an emissions inspection, including OBD system test as appropriate;
c. The proper safety precautions for dynamometer use; and
d. The proper safety precautions for exhaust and calibration gas ventilation procedures.
B. The agreement shall provide for equipment maintenance and service or replacement of components of the certified analyzer system, including dynamometer control devices, optional analyzer equipment, and dynamometer preventative maintenance. Repair or replacement of analyzer system components, other than minimal maintenance items established in the service contract, must be performed by the program coordinator or an authorized agent.
C. The fee to be charged by the program coordinator for each certified analyzer system shall be determined by the department and shall not exceed $5,000 per year, not including optional devices and services and minimal maintenance items established in the service contract.
D. The program coordinator may contract with the inspection station to provide services or equipment beyond the minimum requirements of the contract specified in subsection A of this section.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 29, Issue 24, eff. August 28, 2013; amended, Virginia Register Volume 41, Issue 1, eff. September 25, 2024.
9VAC5-91-670. Inspection station owner requirements (effective during periods without a designated program coordinator).
A. The owner of an emissions inspection station shall enter into an agreement with a manufacturer or its authorized representative to provide the following services to the emissions inspection station at an initial fixed cost per analyzer system to be agreed upon by both parties.
1. Delivery, installation, calibration, and verification of the proper operating condition of an analyzer system which has been certified in writing by the department.
2. Training of all inspectors employed by the emissions inspection station at the time of installation in (i) the proper use, maintenance, and operation of the exhaust analyzer system, (ii) the step-by-step procedure for performing an emissions inspection and any evaporative emissions control system test or fuel filler cap pressure test required, and (iii) proper safety precautions for dynamometer use and exhaust and calibration gas ventilation procedures.
3. Annual updates, except those to be performed by department personnel, of the preexisting internal computer software of the analyzer as specified by the department including, but not limited to:
a. Changes to the emissions standards;
b. Changes to the listed vehicle codes;
c. Changes to the items in the printing system to correspond to changes in other requirements; and
d. Additions or changes to the emissions control equipment list.
B. Emissions inspection stations shall maintain their analyzer systems and dynamometer in good working condition such that they continue to meet certification requirements. Any further arrangements regarding service or maintenance are at the discretion of the emissions inspection station and the manufacturer or equipment vendor.
C. Repair or replacement of analyzer system components, other than for normal maintenance, must be performed by the analyzer system manufacturer or authorized agent.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-675. Inspection station owner requirements (effective during periods with a designated program coordinator).
A. On or after July 1, 2013, and upon notification of designation of a program coordinator, the owner of an emissions inspection station shall enter into an agreement with the program coordinator according to the requirements of 9VAC5-91-665.
B. The station shall provide minimal maintenance items established in the service contract with the program coordinator. The inspection station shall supply any printer paper and toner and gas analyzer probe tips if needed.
C. The station shall supply a safe and fully functional dynamometer at the time certified enhanced analyzer system equipment is provided by the program coordinator. The station shall provide preventative maintenance of the dynamometer until a service contract with a program coordinator is established. Any further arrangements regarding dynamometer service or maintenance are at the discretion of the emissions inspection station and the program coordinator.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-680. Certification of analyzer systems.
A. No analyzer system may be installed, sold or represented as a certified enhanced analyzer system without prior written certification by the department.
B. The analyzer system must have a certificate from the manufacturer that it meets the specifications of 40 CFR Part 85, Subpart W. This certification is necessary so that inspections performed using that analyzer system will qualify applicable vehicles for warranty repair coverage according to the provisions of § 207(b) of the federal Clean Air Act.
C. A person requesting the certification of an emissions analyzer system for use in the Virginia Motor Vehicle Emissions Control Program shall make application to the department using procedures approved by the department.
D. The analyzer system, in order to become certified for use and be used for emissions inspections, shall conform to the equipment specifications and quality control requirements of EPA Technical Guidance document EPA420-B-04-011 (see 9VAC5-91-50) unless requirements contained therein are excluded or superseded by requirements of this chapter as enumerated below.
1. The preconditioning period for all vehicles undergoing an ASM test may be up to 90 seconds. System prompts regarding queuing time are unnecessary. (Ref. EPA420-B-04-011, § 85.2(b)(11))
2. All OBD vehicles shall have engine RPM and emissions-related information read through the OBD connection.
3. Vehicles subject to ASM testing shall receive the ASM 2525 and ASM 5015 modes in that sequence, followed by any second chance testing for which the vehicle is eligible in the same sequence. Second chance tests shall only be performed on vehicles which failed the first chance test within the software specifications of all applicable standards. (Ref. EPA420-B-04-011, § 85.2(e))
4. Dynamometers shall be calibrated through a coast-down procedure every 72 hours. (Ref. EPA420-B-04-011, § 85.4 (b)(1))
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Errata, 18:23 VA.R. 3136 July 29, 2002; amended, Virginia Register Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-690. Span gases; gases for calibration purposes.
A. The gases used by emissions inspection stations in the emissions inspection shall be approved by the department and shall comply with the requirements of this section.
B. The gas concentrations, requirements, and tolerances of gases shall conform to the specifications contained in the EPA Technical Guidance document, EPA420-B-04-011, July 2004 (see 9VAC5-91-50), and each container shall bear a bar-coded label containing concentration and tolerance information as required for calibration and audit purposes.
C. Gases shall be supplied in containers which meet all the provisions of the Occupational Safety and Health Administration as specified in 29 CFR 1910.101, Subpart H.
D. Gases shall be manufactured in accordance with the U.S. Environmental Protection Agency technical report, EPA-AA-TSS-83-8-B (see 9VAC5-91-50).
E. The station owner shall maintain a comprehensive, up-to-date list provided by the department, including addresses and phone numbers, of gas blenders approved by the department.
F. Each analyzer instrument shall be permanently labeled with its optical correction factor (also referred to as "C" factor, propane equivalency factor, or propane to hexane conversion factor), carried to at least two decimal places (within the gas accuracy limits), e.g., (0.52). Factor confirmation shall be made on each assembled analyzer by measuring both N-hexane and propane on assembly line quality checks.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-700. Calibration of exhaust gas analyzers.
The department shall use, and require for use, gases and containers meeting the following parameters, blends, and specifications in the calibration of exhaust gas analyzers:
1. The calibration gases for standardizing instruments shall conform to the provisions outlined in EPA420-B-04-011.
2. Gas analyzers shall pass a two-point gas calibration for HC, CO, CO2 and NO, within 72 hours before each test.
3. Gas analyzers shall pass a five-point gas audit for HC, CO, CO2, and NO at least two times within 12 months, and each time an analyzer system emissions measurement system, sensor, or other electronic components are repaired or replaced in response to an audit failure.
4. The director may reduce the frequency of calibrations in subdivision 2 of this section and audits in subdivision 3 of this section or both if evidence indicates accuracy would not be adversely affected.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.
9VAC5-91-710. Upgrade of analyzer system.
A. Any requirement to upgrade a certified emissions analyzer system beyond the specifications and requirements described in this chapter and EPA420-B-04-011 shall apply to all such systems certified under this chapter and shall require an amendment to this chapter except for software or equipment upgrades provided under 9VAC5-91-670 or 9VAC5-91-675 as applicable.
B. Such upgrade may include, but not be limited to, enhanced on-board diagnostic (OBD) testing equipment and electronic vehicle identification systems such as video and audio processes.
Statutory Authority
§ 46.2-1180 of the Code of Virginia; § 182 of the Clean Air Act; 40 CFR Part 51, Subpart S.
Historical Notes
Derived from Virginia Register Volume 13, Issue 5, eff. January 24, 1997; amended, Virginia Register Volume 18, Issue 20, eff. October 1, 2002; Volume 29, Issue 24, eff. August 28, 2013.