LIS

Code of Virginia

Creating a Report: Check the sections you'd like to appear in the report, then use the "Create Report" button at the bottom of the page to generate your report. Once the report is generated you'll then have the option to download it as a pdf, print or email the report.

Code of Virginia
Title 45.2. Mines, Minerals, and Energy
Chapter 8. Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc.
4/27/2025

§ 45.2-802. Hydraulic hoses.

Every hydraulic hose used on equipment purchased after January 1, 1986, shall be clearly stamped or labeled by the hydraulic hose manufacturer to indicate the manufacturer's rated pressure in pounds per square inch (psi) Every hose purchased after January 1, 1989, shall have the rated pressure permanently affixed on the outer surface of the hose and repeated at least every two feet. Every hose purchased and installed on an automatic displacement hydraulic system shall either (i) have a four-to-one safety factor based on the ratio between minimum burst pressure and the setting of the hydraulic unloading system, such as a relief valve, or (ii) meet the minimum hose pressure requirements set by the hydraulic equipment manufacturer per the applicable hose standards for each type of equipment. No hydraulic hose shall be used in an application where the hydraulic unloading system is set higher than the hose's rated pressure.

1985, c. 612, § 45.1-88.1; 1988, c. 301; 1994, c. 28, § 45.1-161.125; 2021, Sp. Sess. I, c. 387.

The chapters of the acts of assembly referenced in the historical citation at the end of this section may not constitute a comprehensive list of such chapters and may exclude chapters whose provisions have expired.