LIS

Administrative Code

Creating a Report: Check the sections you'd like to appear in the report, then use the "Create Report" button at the bottom of the page to generate your report. Once the report is generated you'll then have the option to download it as a pdf, print or email the report.

Virginia Administrative Code
Title 9. Environment
Agency 5. State Air Pollution Control Board
Chapter 40. Existing Stationary Sources
12/26/2024

9VAC5-40-5880. Reporting.

A. The provisions of 9VAC5-40-5840 (Notification, records and reporting) apply.

B. Except as provided in 9VAC5-40-5820 C 2 a (2), the provisions of subsections C through I of this section apply.

C. Each owner subject to the requirements of this article shall submit an initial design capacity report to the board.

1. The initial design capacity report shall be submitted no later than June 30, 1999.

2. The initial design capacity report shall contain the following information:

a. A map or plot of the landfill, providing the size and location of the landfill, and identifying all areas where solid waste may be landfilled according to the permit issued by the department under Part V (9VAC20-81-400 et seq.) of 9VAC20 Chapter 81 (Solid Waste Management Regulations);

b. The maximum design capacity of the landfill. Where the maximum design capacity is specified in a permit issued by the department under Part V (9VAC20-81-400 et seq.) of 9VAC20 Chapter 81 (Solid Waste Management Regulations), a copy of the permit specifying the maximum design capacity may be submitted as part of the report. If the maximum design capacity of the landfill is not specified in the permit, the maximum design capacity shall be calculated using good engineering practices acceptable to the board. The calculations shall be provided, along with the relevant parameters as part of the report. The board may request other reasonable information as may be necessary to verify the maximum design capacity of the landfill.

3. An amended design capacity report shall be submitted to the board providing notification of an increase in the design capacity of the landfill within 90 days of an increase in the maximum design capacity of the landfill to or above (i) 1.0 million megagrams and 1.0 million cubic meters in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 2.5 million megagrams and 2.5 million cubic meters in the remaining areas of the Commonwealth. This increase in design capacity may result from an increase in the permitted volume of the landfill or an increase in the density as documented in the annual recalculation required in 9VAC5-40-5890 H.

D. Each owner subject to the requirements of this article shall submit an NMOC emission rate report to the board initially and annually thereafter, except as provided for in subdivisions D 1 b or D 3 of this section. The board may request such additional information as may be necessary to verify the reported NMOC emission rate.

1. The NMOC emission rate report shall contain an annual or five-year estimate of the NMOC emission rate calculated using the formula and procedures provided in 9VAC5-40-5860 B or C, as applicable.

a. The initial NMOC emission rate report shall be submitted by June 30, 1999, and may be combined with the initial design capacity report required in subsection C of this section. Subsequent NMOC emission rate reports shall be submitted annually thereafter, except as provided for in subdivisions D 1 b and D 3 of this section.

b. If the estimated NMOC emission rate as reported in the annual report to the board is less than (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth in each of the next five consecutive years, the owner may elect to submit an estimate of the NMOC emission rate for the next five-year period in lieu of the annual report. This estimate shall include the current amount of solid waste-in-place and the estimated waste acceptance rate for each year of the five years for which an NMOC emission rate is estimated. All data and calculations upon which this estimate is based shall be provided to the board. This estimate shall be revised at least once every five years. If the actual waste acceptance rate exceeds the estimated waste acceptance rate in any year reported in the five-year estimate, a revised five-year estimate shall be submitted to the board. The revised estimate shall cover the five-year period beginning with the year in which the actual waste acceptance rate exceeded the estimated waste acceptance rate.

2. The NMOC emission rate report shall include all the data, calculations, sample reports and measurements used to estimate the annual or five-year emissions.

3. Each owner subject to the requirements of this article is exempted from the requirements of subdivisions D 1 and 2 of this section, after the installation of a collection and control system in compliance with 9VAC5-40-5820 C 2, during such time as the collection and control system is in operation and in compliance with 9VAC5-40-5822 and 9VAC5-40-5850.

E. Each owner subject to the provisions of 9VAC5-40-5820 C 2 a shall submit a collection and control system design plan to the board within one year of the first report, required under subdivision D of this section, in which the emission rate is greater than or equal to (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth, except as follows:

1. If the owner elects to recalculate the NMOC emission rate after Tier 2 NMOC sampling and analysis as provided in 9VAC5-40-5860 B 3 and the resulting rate is less than (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth, annual periodic reporting shall be resumed, using the Tier 2 determined site-specific NMOC concentration, until the calculated emission rate is greater than or equal to (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth, or the landfill is closed. The revised NMOC emission rate report, with the recalculated emission rate based on NMOC sampling and analysis, shall be submitted within 180 days of the first calculated exceedance of the emission rate applicability criteria.

2. If the owner elects to recalculate the NMOC emission rate after determining a site-specific methane generation rate constant (k), as provided in Tier 3 in 9VAC5-40-5860 B 4, and the resulting NMOC emission rate is less than (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth, annual periodic reporting shall be resumed. The resulting site-specific methane generation rate constant (k) shall be used in the emission rate calculation until such time as the emissions rate calculation results in an exceedance. The revised NMOC emission rate report based on the provisions of 9VAC5-40-5860 B 4 and the resulting site-specific methane generation rate constant (k) shall be submitted to the board within one year of the first calculated emission rate exceeding (i) 23 megagrams per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams per year in the remaining areas of the Commonwealth.

F. Each owner of a controlled landfill shall submit a closure report to the board within 30 days of waste acceptance cessation. The board may request additional information as may be necessary to verify that permanent closure has taken place in accordance with the requirements of 9VAC20-81-160. If a closure report has been submitted to the board, no additional wastes may be placed into the landfill without obtaining a permit issued by the department under Part V (9VAC20-81-400 et seq.) of 9VAC20 Chapter 81 (Solid Waste Management Regulations).

G. Each owner of a controlled landfill shall submit an equipment removal report to the board 30 days prior to removal or cessation of operation of the control equipment.

1. The equipment removal report shall contain all of the following items:

a. A copy of the closure report submitted in accordance with subsection F of this section;

b. A copy of the initial compliance test report demonstrating that the 15-year minimum control period has expired; and

c. Dated copies of three successive NMOC emission rate reports demonstrating that the landfill is no longer producing (i) 23 megagrams or greater of NMOC per year in the Northern Virginia Volatile Organic Compound Emissions Control Area or (ii) 50 megagrams or greater of NMOC per year in the remaining areas of the Commonwealth.

2. The board may request such additional information as may be necessary to verify that all of the conditions for removal in 9VAC5-40-5820 C 2 e have been met.

H. Each owner of a landfill seeking to comply with 9VAC5-40-5820 C 2 using an active collection system designed in accordance with 9VAC5-40-5820 C 2 b shall submit to the board annual reports of the recorded information in subdivisions H 1 through H 6 of this section. The initial annual report shall be submitted within 180 days of installation and startup of the collection and control system, and shall include the initial compliance test report. For enclosed combustion devices and flares, reportable exceedances are defined under 9VAC5-40-5890 E.

1. Value and length of time for exceedance of applicable parameters monitored under 9VAC5-40-5870 C, D, E, and F.

2. Description and duration of all periods when the gas stream is diverted from the control device through a bypass line or the indication of bypass flow as specified under 9VAC5-40-5870.

3. Description and duration of all periods when the control device was not operating for a period exceeding one hour and length of time the control device was not operating.

4. All periods when the collection system was not operating in excess of five days.

5. The location of each exceedance of the 500 parts per million methane concentration as provided in 9VAC5-40-5822 A 4 and the concentration recorded at each location for which an exceedance was recorded in the previous month.

6. The date of installation and the location of each well or collection system expansion added pursuant to subdivisions C 3, D, and E 4 of 9VAC5-40-5850.

I. Each owner seeking to comply with 9VAC5-40-5820 C 2 a shall include the following information with the initial compliance test report:

1. A diagram of the collection system showing collection system positioning including all wells, horizontal collectors, surface collectors, or other gas extraction devices, including the locations of any areas excluded from collection and the proposed sites for the future collection system expansion;

2. The data upon which the sufficient density of wells, horizontal collectors, surface collectors, or other gas extraction devices and the gas mover equipment sizing are based;

3. The documentation of the presence of asbestos or nondegradable material for each area from which collection wells have been excluded based on the presence of asbestos or nondegradable material;

4. The sum of the gas generation flow rates for all areas from which collection wells have been excluded based on nonproductivity and the calculations of gas generation flow rate for each excluded area; and

5. The provisions for increasing gas mover equipment capacity with increased gas generation flow rate, if the present gas mover equipment is inadequate to move the maximum flow rate expected over the life of the landfill; and

6. The provisions for the control of off-site migration.

Statutory Authority

§ 10.1-1308 of the Code of Virginia; §§ 110, 111, 123, 129, 171, 172, and 182 of the Clean Air Act; 40 CFR Parts 51 and 60.

Historical Notes

Derived from Virginia Register Volume 12, Issue 11, eff. April 1, 1996; amended, Virginia Register Volume 15, Issue 12, eff. April 1, 1999; Volume 20, Issue 8, eff. January 29, 2004; Volume 27, Issue 23, eff. August 17, 2011.

Website addresses provided in the Virginia Administrative Code to documents incorporated by reference are for the reader's convenience only, may not necessarily be active or current, and should not be relied upon. To ensure the information incorporated by reference is accurate, the reader is encouraged to use the source document described in the regulation.

As a service to the public, the Virginia Administrative Code is provided online by the Virginia General Assembly. We are unable to answer legal questions or respond to requests for legal advice, including application of law to specific fact. To understand and protect your legal rights, you should consult an attorney.